SOPs Banner

Standard Operating Procedures (SOPs) – Heterogenous Sequence Task (HST)

Title: Standard Operating Procedure – Heterogenous Sequence Task (HST)
Author: MouseTRAP Team
Date: 10/28/2021
Version: 1
Abstract: The heterogenous long sequence task is used measure complex motor learning and sequential response/response chain learning. The task is performed in specially designed touchscreen-based automated chambers with five response locations using food reinforcers to maintain performance. The sequence task requires the subject make five nose-pokes to white square stimuli appearing in five locations sequentially from left to right.
DOI: 10.58064/6r2v-fs32
Link to Full SOP: HetSequence-v1
Please login or register to request access to the PDF.

Please note that the ABETII file names in the SOPs may differ across different users and facilities. Full SOPs are available to members of touchscreencognition.org.

Version Notes

[DATE]: Version [#]

  • Adjusted the After reward pause from 5s to 10s
    • Reasoning is explained at the end of the SOP, but was based on fibre photometry recordings that demonstrated mice needed more time to baseline
  • Included an additional formula for more data we can analyze: Premature Responses
  • Added another method to run the stimulus duration probe
  • Clarified details about the Inter Trial Interval
    • Specifically, we made it clearer that the ITI is variable, rather than a constant duration between each trial